• Hc-B104A Medical Equipment 96 Nucleic Acid Samples Nucleic Acid Test Extractor Magnetic Bead Method Automaic Nucleic Acid Extraction System
  • Hc-B104A Medical Equipment 96 Nucleic Acid Samples Nucleic Acid Test Extractor Magnetic Bead Method Automaic Nucleic Acid Extraction System
  • Hc-B104A Medical Equipment 96 Nucleic Acid Samples Nucleic Acid Test Extractor Magnetic Bead Method Automaic Nucleic Acid Extraction System
  • Hc-B104A Medical Equipment 96 Nucleic Acid Samples Nucleic Acid Test Extractor Magnetic Bead Method Automaic Nucleic Acid Extraction System
  • Hc-B104A Medical Equipment 96 Nucleic Acid Samples Nucleic Acid Test Extractor Magnetic Bead Method Automaic Nucleic Acid Extraction System

Hc-B104A Medical Equipment 96 Nucleic Acid Samples Nucleic Acid Test Extractor Magnetic Bead Method Automaic Nucleic Acid Extraction System

Classification: Biological Diagnostics
Type: Nucleic Acid Extraction System
Certification: CE
Group: All People
Name: Nucleic Acid Extractor
Ambient Temperature: 15~32ºC
Diamond Member Since 2020

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
HC-B104A
Relative Humidity
20% ~ 80%
Input Voltage
200-240V , 50/60Hz
Processing Volume
20μl-1000μl
Number of Magnets
96 Pieces
Sample Throughput
1-96 Samples
Magnetic Bead Recovery Rate
> 98%
Module Temperature Control Accuracy
±0.5ºC
Extraction Time
Extract 8-40 Minutes/Round (Depending on The Reage
Transport Package
Aluminum Case
Trademark
Happycare
Origin
China

Product Description

HC-B104A Medical equipment 96 nucleic acid samples nucleic acid test extractor Magnetic Bead Method automaic  Nucleic Acid Extraction System
 

Features for HC-B104A Medical equipment 96 nucleic acid samples nucleic acid test extractor Magnetic Bead Method automaic  Nucleic Acid Extraction System:

 

HC-B104A nucleic acid extraction system is a biomedical instrument specially used for automatic magnetic bead method nucleic acid extraction. You only need to add the samples to be extracted to the matching kit, put the kit into HC-B104A, run the program that comes with the instrument, and complete a round of extraction of 96 nucleic acid samples in 15-40 minutes. The unique cryopreservation function of HERO96 nucleic acid extraction system can ensure the quality of the extracted product when you cannot process the extracted nucleic acid in time.

Working conditions

Ambient temperature: 15~32ºC

Relative humidity: 20% ~ 80%

Input voltage: 200-240V , 50/60Hz

Technical performance index

Operation interface: Full Chinese Android system touch operation

Processing volume: 20μl-1000μl

Magnetic rod magnetic: More than 4500Gs 

Magnet pitch: The inner spacing is 9±0.02mm, the outer spacing is 12.6±0.04mm

Number of magnets: 96 pieces

Sample throughput: 1-96 samples

Magnetic bead recovery rate: > 98%

Orifice type: 96-well 2.2ml sterile enzyme-free deep well plate.

Heating temperature: Semiconductor cooling sheet heating module, the temperature control range is 4ºC to 120

Shock mixing: Using up and down stirring and shaking mode, multi-stage adjustable, and the shaking amplitude can be adjusted with the volume of the reagen

Module temperature control accuracy: ±0.5ºC

Way of working: Magnetic bead method for nucleic acid extraction

Extraction time: Extract 8-40 minutes/round (depending on the reagents used)

Internal procedures: Can be stored and stored> 500, and the program can be set to start from any step, without repeated program editing.

Oscillation module: Equipped with two high-frequency oscillation modules, 5 speeds of magnetic rod frame, 3 speeds of magnetic frame

Safety protection: The instrument is fully automatic and closed operation. During use or experimentation by experimenters, do not open the front safety door. If you want to open it, please pause the running program first

Anti-cross contamination: Built-in air duct, anti-pollution wetted plate, high efficiency filter, negative pressure exhaust function

Flashlight: Have

UV irradiation: Have

Dimensions: 820.7 mm x 527mm x458.1 mm

Weight: 61.6Kg

Qualification: The manufacturer has passed ISO9001, ISO13485 quality system certification, and the products have passed China CFDA certification and EU CE certification (safety and electromagnetic compatibility certification

Pictures for HC-B104A Medical equipment 96 nucleic acid samples nucleic acid test extractor Magnetic Bead Method automaic  Nucleic Acid Extraction System:
Hc-B104A Medical Equipment 96 Nucleic Acid Samples Nucleic Acid Test Extractor Magnetic Bead Method Automaic Nucleic Acid Extraction SystemHc-B104A Medical Equipment 96 Nucleic Acid Samples Nucleic Acid Test Extractor Magnetic Bead Method Automaic Nucleic Acid Extraction SystemHc-B104A Medical Equipment 96 Nucleic Acid Samples Nucleic Acid Test Extractor Magnetic Bead Method Automaic Nucleic Acid Extraction SystemHc-B104A Medical Equipment 96 Nucleic Acid Samples Nucleic Acid Test Extractor Magnetic Bead Method Automaic Nucleic Acid Extraction SystemHc-B104A Medical Equipment 96 Nucleic Acid Samples Nucleic Acid Test Extractor Magnetic Bead Method Automaic Nucleic Acid Extraction System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now