Hc-C014 Portable Spot Check Patient Monitor Handheld Personal ECG Monitor

Product Details
Customization: Available
Classification: Patient Monitor
Certification: CE
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
Minor Customization
The supplier provides minor customization services such as logo, graphic, package
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (15)
  • Hc-C014 Portable Spot Check Patient Monitor Handheld Personal ECG Monitor
  • Hc-C014 Portable Spot Check Patient Monitor Handheld Personal ECG Monitor
  • Hc-C014 Portable Spot Check Patient Monitor Handheld Personal ECG Monitor
  • Hc-C014 Portable Spot Check Patient Monitor Handheld Personal ECG Monitor
  • Hc-C014 Portable Spot Check Patient Monitor Handheld Personal ECG Monitor
  • Hc-C014 Portable Spot Check Patient Monitor Handheld Personal ECG Monitor
Find Similar Products

Basic Info.

Model NO.
HC-C014
Group
Middle-aged and Old
Power Source
Electricity
Products Name
Handheld Personal ECG Monitor
Transport Package
Standard
Specification
standard
Trademark
Happycare
Origin
China
Production Capacity
10000

Product Description

HC-C014  Handheld Personal ECG Monitor/Portable Spot Check Patient Monitor



Features for HC-C014  Handheld Personal ECG Monitor/Portable Spot Check Patient Monitor:

Snail design with NIBP, SpO2, PR, TEMP, Glucose and ECG(Optional).

Wireless communication to smartphone or tablet

Easy to use Android and Apple mobile app

Data to be saved on phone or uploaded to PC

Inbuilt Li-ion battery for continuous operation

Medical kit available for home visit

Technical Specification

NIBP

Measuring m ethod: Oscillometric Technique

Measuring range: 0mmHg~300mmHg

Measuring accuracy: ±3mmHg

Inflation time: <20 s(typical adult cuff)

Overpressure protection limit: 300mmHg

Measruing range:

SYS : 30mmHg~270mmHg

DIA : 10mmHg~220mmHg

Cuff type: Adult, Ped iatric, Neonate

Temperature

Measuring range: 32 ºC ~43 ºC

Measuring accuracy: ±0.2 ºC

Response tim e: <5s

Probe: Infrared ear probe

SpO2

Techni q ue: Dual-wavelength LED

SpO2 measuring range: 0%~100%

SpO2 measuring accuracy: ±2%(range from 70%~100%)

PR measuring range: 30bpm~250bpm

PR measuring accuracy ±2bpm

Sensor type: Adult, Pediatric, Neonate

Measuring m ethod:

MAP: 20mmHg~235mmHg

Blood Glucose

Measuring range: 20 - 600 mg/100ml (1.1-33.3mmol /L)

Measuring time: 10s

Sample volume: ≥ 0.7 microlitre

Electrochemical biosensor method

ECG

Measuring range: 30bpm~240bpm

Measuring accuracy: ±2bmp or±2%

Display scale: 5.0mm/mV±10%

Common-model rejection ratio: <60dB

Option: ECG leadwire

 

 

 Pictures for HC-C014  Handheld Personal ECG Monitor/Portable Spot Check Patient Monitor:
Hc-C014 Portable Spot Check Patient Monitor Handheld Personal ECG MonitorHc-C014 Portable Spot Check Patient Monitor Handheld Personal ECG Monitor

Hc-C014 Portable Spot Check Patient Monitor Handheld Personal ECG Monitor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier