Hc-E005b ISO Approved Movable ICU Anesthesia Machine with Ventilator

Product Details
Customization: Available
Used for: Adult
Gas Source: O2: 0.27~0.55MPa
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
Minor Customization
The supplier provides minor customization services such as logo, graphic, package
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (15)
  • Hc-E005b ISO Approved Movable ICU Anesthesia Machine with Ventilator
  • Hc-E005b ISO Approved Movable ICU Anesthesia Machine with Ventilator
  • Hc-E005b ISO Approved Movable ICU Anesthesia Machine with Ventilator
  • Hc-E005b ISO Approved Movable ICU Anesthesia Machine with Ventilator
  • Hc-E005b ISO Approved Movable ICU Anesthesia Machine with Ventilator
  • Hc-E005b ISO Approved Movable ICU Anesthesia Machine with Ventilator
Find Similar Products

Basic Info.

Model NO.
HC-E005B
Flow Meter
O2: 0.1~2L/Min 2.5~10L/Min
Transport Package
Carton
Trademark
Happycare
Origin
China
Production Capacity
10000

Product Description

HC-E005B  ISO Approved Hospital use movable ICU anesthesia machine with ventilator

Features for HC-E005B  ISO Approved Hospital use movable ICU anesthesia machine with ventilator:

 

1. Main body                 High-strength engineering plastic rack, light,

beautiful and corrosion resistant

2. Gas source                 O2: 0.27~0.55MPa    N2O: 0.27~0.55MPa

3. Scope of application          adult, child

4. Flow meter                 O2: 0.1~1.0L/min   1.1~10L/min

N20: 0.1~1.0L/min   1.1~10L/min

5. O2, N2O linkage and N2O Stopper

When using nitrous oxide, oxygen concentration>25%;

When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.

6. Respiratory circuit            working mode: all-close, semi-close, semi-open

releasing pressure: 0.5~7 kPa

7. Respiratory Bellows         bellows for adults, bellows for children

tidal volume range:0~1,500 ml

8. Flow rate of rapid oxygen supply   25~75L/min

9. Low oxygen pressure alarm     There will be sound alarm when the oxygen pressure < 0.2MPa

10. Vaporizer                  it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane,Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.

Ventilator:

1. Display mode               High-definition TFT color LCD screen display

2. Ventilation  mode           IPPV, SIPPV, SIMV, PEEP, MANUAL,

SIGH, (IMV, VCV, PCV)

3. Parameters for ventilation monitoring  tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance,flow-volume oop,pressure-volume loop)

4. Ventilation parameters       Tidal volume      50~1500 ml (20~1500 ml)

Rate         1~99 bpm

SIMV rate   2~20 bpm

I:E          2:1~1:8 (4:1~1:8)

Inspiratory trigger pressure -1.0~2.0Kpa

PEEP        0~2.0Kpa

Pressure Range  1.0~6.0Kpa

SIGH        1.5 times the inspiratory time (70-150 adjustable)

Inspiratory platform 0~50%

5. Monitoring of oxygen concentration   21%~100%

6. Security Alarm System

Oxygen Concentration alarm     upper limit setting range  21%~100%

low limit setting range   10%~80%

Airway pressure alarm          upper limit setting range  0.3~6.0 kPa

low limit setting range   0.2~5.0 kPa

Per-minute ventilation volume alarm       upper limit setting range 3.0~30L/min

low limit setting range   1.0~10L/min

Sustained high-pressure alarm       it will give alarm when stress have consistently been higher than 2.5 kPa

Suffocation alarm              it will give sound and light alarm if there

is no tidal volume input for 15 seconds

Power alarm

7. (Mechanical Arms)         

8. (End-expiratory CO2 monitoring) 

9. Power                        AC 220V±10%     50Hz±1Hz

                             (UPS, Storage battery)

Pictures for  HC-E005B  ISO Approved Hospital use movable ICU anesthesia machine with ventilator:
Hc-E005b ISO Approved Movable ICU Anesthesia Machine with Ventilator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier