Features for HC-C008 China 12.1 inch CTG Fetal Doppler Monitor/ Doppler fetal monitor
Alarms for fetal tachycardia or bradycardia,low power and paper missing.
12.1 inch TFT color screen, which can be folded up to 90 degrees.
152 mm thermal printing paper.
DSP technology, real-time identify and measurement for FHR, accurate and reliable results.
High sensitive and water-proof FHR probe with built-in FAS function (Fetal Acoustic Stimulator).
Fetal movement displaying and printing function.
Manual and automatic fetal movement recording.
24 hours data storage, which can be played back and printed.
Special patient and clinical event marking.
Built-in 16.8V lithium battery which applicable for AC and DC.
Supports both cable and wireless network connection and can be used with the central monitoring station to set up a network system.
Advanced technology, realtime identify and measurement for FHR, accurate and reliable results
Multi-crystals, wide beam form high sensitivity ultrasound transducer, 1MHz pulsed wave, low ultrasound power, safer to the fetus
24 hours data storage which can be playback and printed
Fetal acoustic stimulator function, which can easily and safely wake up the sleeping fetus when monitoring
A standard patient event marker and a clinical event marking button to separately mark clinical events.
Wide range of applying voltage (100-240 V)
Manual / automatic fetal movement detection
3 in 1 transducers, avoid twisting.
Many alarm functions are included: The monitoring time over alarm, no paper alarm.
Optionals
Twins monitoring
Maternal SpO2, NIBP, PR, ECG, TEMP, RESP
Specification
Fetal Heart Rate:
Transducer: Multi-crystals, pulsed doppler , high sensitive
Strength: <5mW/cm2
Working frequency: 1.0MHz
Signal processing: special DSP system and modern recognization.
Measurement range: 30~210 bpm
Alarm Range:
High limit: 160,170,180,190 bpm
Low limit: 90,100,110,120 bpm
Maximum audio output power : 1.5 Watt
Toco: Measurement range: 0~100 units
Resolution: 1
Fetal Movement: Button Hand Count ( Automatic cumulative number of movements
Maternal SpO2 measure: Measure scope : 70%~99%. Measure accuracy: ±3%
Pregnant HR Measure: Measure scope: 30bpm~240bpm. Measure accuracy: ±2 bpm
NIBP measure:
a) NIBP-SYS (6.7~32.0Kpa) (50~240mmHg)
b) NIBP-DIA (3.4~26.6Kpa) (25~200mmHg)
c) NIBP-MEAN (2.0~24.0ka (15~180mmHg)
NIBP Accuracy: ±1.1kPa (±8mmHg) or ±5% of the results, take the bigger one.
Maximum Mean error: ±5mmHg
Maximum Standard deviation 8mmHg
Pulse Rate Accuracy: Maximum Mean error: ±2bpm
Measure accuracy: ±2 bpm or ±5% of the results, take the bigger one.
Measure mode: Auto, Manual
Power: a.c.100-240V,50/60Hz or 8.4 Li-LON
Power Consumption: < 20W
Dimension: 295W×240D×73H(mm)
Net weight: 1.75kg
Working Environment: Temperature: 5~40°C. Relative humidity: 10~80%.