• Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals
  • Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals
  • Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals
  • Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals
  • Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals

Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals

Syringe: Na
Blood Sampling Needle: Na
Breathing Pattern: Na
Ultrasonic Probe: in 8.0 MHz
Transport Package: Carton Box
Trademark: Happycare
Diamond Member Since 2020

Suppliers with verified business licenses

Trading Company
  • Overview
  • Certifications
  • Packaging & Shipping
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
HC-R032
Origin
China
Production Capacity
10000pieces/Month

Product Description

HC-R032 Veterinary Doppler Blood Pressure /pet doppler  ambulatory blood pressure equipment for animals

 

Features for HC-R032 Veterinary Doppler Blood Pressure /pet doppler  ambulatory blood pressure equipment for animals:

1. Imported manometer in high quality
1.Ultrasonic probe in 8.0 MHz
2.Five pieces of oxford fabric cuffs
3.Ultrasonic host 
4.Ultrasonic gel 
5.Earphone 
6.Power adapter 
7.Packing of aluminum alloy box 
Operation of the Doppler blood pressure meter
1. Inflation : Close the valve and then slowly press the gasbag
2. deflation: According to the direction of the following photo , open the valve gently press the gasbag until all of the gas in the cuff has been deflated.
3. the connection and loosen of the cuffs: connect the cuffs loose the cuffs as the following pictures show.

 Procedures to test pets blood pressure 
1.Cutting off fur on volar pad especially fur beneath the first toe and the cleaner, the better. And then smear couplant on the midline of the foot.
2.Smearing much couplant on probe and put the probe on the midline. Then you can hear sound like "so -so -so".If not ,please remove the probe till the sound can be heard .
3.When pets in examination in the section of outpatient ,they are always in tension .At this time ,It is advice to do the examination with 3 medical staffs :one person is to keep pets quiet , one is to use the probe to find pets pulse and the third person is to inflate and deflate the pressure meter .
When monitoring pets in operation, there is needing only one person to do blood pressure meter every 5-10 minutes.
4.Cuff should be placed above the pet forelimb wrist (proximal to the heart ).The indicatrix on the end of cuff should be in the range of the circumference. If not,the tested blood pressure will be much higher (the cuff is large compared with the limb ) or much lower ( the cuff is small  compared with the limb )   
5.Close the walve and begin the inflation. When you do not hear the sound like "so-so-so",continue to inflate 20mmHg more and then open the walve and begin to record the systolic pressure .
6.When in slow and continuous deflation, diastolic pressure can be recorded .However ,diastolic pressure is easily affected by many factors such as probe's position ,degree of tightness and so on so that it is not easy to hear the sound of the diastolic pressure . And this is due to the Doppler theory. But a experienced doctor with many times practice may can test the diastolic pressure .
7. It is advice to do the examination in room with heating installation in winter because room temperature is below 10 degree  or pets'skin temperature is too low , the examination will be influenced and it is not easy to hear the sound of "so -so -so". I f pets are too small or their vessels are narrow ,it is usual that blood flow can not be heard .
8.The usual blood pressure range for cats and dogs is from 110mmHg to 160mmHg .

Notes
Probe:
Please turn off the power immediately after usage. The probe should be protected carefully.Do not crash and collide the probe(the probe is very expensive ) with other things. Avoiding to damage the chip in the probe .
Couplant:
It is not allowed to use ECG viscose,baby oil and other oils except couplant . Because those oil such as ECG viscose,baby oil will corrode and damage the probe.
Battery:
When power light become dark and speaker stop work ,it is necessary to charge the battery .
Specifications :
1.Measuring range:0mGs-199.9mGs
2.Frequency of the probe: 8.0MHz
3. Specification of the blood pressure cuff
Range: No.1 4.2cm-7.1cm
           No.2 5.4cm-9.1cm
           No.3 6.9cm-11.7cm
           No.4 9cm-13cm
           No.5 12cm-16cm
4. Rechargeable battery voltage:7.4V 1500mAh
5. AC input: 100-240V 50/60Hz  DC output DC8.4V,1000mA
6. Continuous working time :> 8 hours
Cleaning
1.Probe :a.Wipe off viscose softly with a napkin after usage 
         b.Use alcohol swabs to swipe the probe softly for sterilization. 
       c.Before using disinfectant or bactericide to sterilize the probe you should consult the manufacturer.
2.Host:Please prevent the body from water when cleaning the host.

 

Pictures for HC-R032 Veterinary Doppler Blood Pressure /pet doppler  ambulatory blood pressure equipment for animals:
Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals
Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals
Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals
Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals

 

Certifications

Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals

Packaging & Shipping

Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals

Company Profile

Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for AnimalsHc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for AnimalsHc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals

Our Advantages

Hc-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals

FAQ

1. How to place order of  HC-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals    ?
A: Firstly we confirm product details and then send the Proforma Invoice,
     You make payment to us through Alibaba Trade Assurance or T/T, Western Union or MoneyGram,
     after we confirm your payment then ship the product to you once finished production.
 
2. For  HC-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals     product, What's  the minimum order  quantity (MOQ)?
A: For disposable material,We have our own MOQ,For our HC-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals , our MOQ:1pc,
 
3. What is your warranty?
A: For most products the warranty is for 12 months, some products we provide 18 months warranty.
     For  HC-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals  , we provide 12 months warranty.

4. What's your delivery time?
A: Generally it is 5 working days if goods in stock. within 10 working days if the goods need production,
 And also the delivery time depands on quantity. For  HC-R032 Veterinary Doppler Blood Pressure /Pet Doppler Ambulatory Blood Pressure Equipment for Animals , the delivery  time is 10  working days .

5. How to ship the product?
A: The shipping way normally depand on your quantity,total CBM and weight.
     We have our own shipping company to provide best shipping cost and efficient way. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now