Customization: | Available |
---|---|
Charge Time: | 8 Sec. to 150j; 10 Sec. to 200j (New Battery) |
Energy Sequence: | 150, 150, 200j |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
HC-C017 Hot sale Automated AED Automated External Defibrillator
Features for HC-C017 Hot sale Automated AED Automated External Defibrillator:
HC-C017 AED Defibrillator (Automatic External Defibrillator) is a defibrillation device, which is safe, portable and easy to use. It can be applied in family and public place to give first aid for the sudden death symptom. Combined with advanced ECG analytical technique, the defibrillator can analyze the patients ECG, make a judgement for the patients cardiac condition and indicate whether the defibrillation is needed and the defibrillation strength. It can not only enhances the success rate of defibrillation, but also reduce the injury of defibrillation to heart to the utmost extent.There is low requirement for the operator to use the device. The defibrillator will guide the operator to carry out defibrillation treatment via voice prompt step by step, give safety alert if the occasion arises. It can carry out early defibrillation treatment effectively and protect the operator farthest, being very applicable to the emergency treatment for the sudden cardiac death patient in family and public place.
Three-step defibrillation process
Two-button operation
Extensive voice and visual prompts for the operator
Biphasic energy output
Lock-out protection to prevent inadvertent defibrillation
PC-based event review (optional)
Multilingual selections are available. (optional)
Output |
Biphasic Truncated Exponential |
Energy Sequence |
150, 150, 200J |
Charge Time |
8 sec. to 150J; 10 sec. to 200J (New Battery) |
Analysis Time |
9 sec. |
The maximum time from the initiation of rhythm analysis to readiness for discharge with a new battery |
|
The maximum time from the initiation of rhythm analysis to readiness for discharge after 6 shocks |
Less than 35 seconds |
The maximum time from initially switching power on to readiness for discharge |
Less than 25 seconds |
Audible Prompts |
22 audible prompts |
Visual Prompts |
LED prompts |
Controls |
Two buttons-ON/Off, Shock |
Output Energy Accuracy |
±15% into any impedance from 25 to 175Ω |
The Maximum Voltage |
1200±50V |
Output disabled when the patient impedance is outside limits |
20Ωto 200Ω |
Physical |
|
Dimensions |
303*216*89mm |
Weight |
2.0kg |
Operating Temperature |
0°C to 40°C |
|
Relative humidity between 30% and 95% (non-condensing) |
Storage Temperature (without battery) |
-20°C to 55°C |
Storage Humidity (without battery) |
Up to 95% (non-condensing) |
Battery |
|
Part No. |
CR123A-4*2 |
Non-rechargeable |
12V DC, 2.8Ah |
Capacity |
At 150 Joules |