HC-R026 Animal ophthalmology instrument Eyelash Electrolysis Machine for Animals/Vet eyelash removal machine
Features for the HC-R026 Animal ophthalmology instrument Eyelash Electrolysis Machine for Animals/Vet eyelash removal machine:
Eyelash electrolytic apparatus is special for pets, output voltage of main machine is 6V output DC50mAplus 50mA. By DC electrolysis principle, electrolytic water and salt of body tissue, making the tissue around hair follicle relaxed, so as to achieve the purpose of trichiasis pulling completely. It's easy operation, short treatment time, noninvasive, no bleeding, fast recovery,etc. You can adjust the electrolytic current according to pets specific conditions, which're widely applied for clinic treatments. Eyelash electrolytic apparatus(for pets): main machine,treatment pen,electrode holder,power line,foot switch. |
Operation procedure
a) connecting power and foot switch, entering treatment pen to electrode socket of front panel.
b)electrolysis needle need to be disinfected by 75% alcohol and 2% Glutaric dialdehyde, electrode holder need be wrapped by physiological saline wet gauze.
c) with 75% alcohol on eyelid skin disinfection(Don't make alcohol enter into eye)
d) electrode holder wrapped in wet gauze , caught in the side of the cheek skin for an electrolytic trichiasis.
e) open power switch, along the direction of eyelash, electrolysis needle pierce the eyelash root 1~2mm, stepped on the foot switch, after power-on 20s~30s, there is fine white foam from the eyelash at electrode needle place; If no foam, please turn the button of "current adjusting button" on front panel along the clockwise direction, to the large current.
f) after pulling needle, using eyelash tweezer to pull out trichiasis after electrolysis. If feel hard to pull, it will show the tissue around follicle still not be slack, please electrolysis again.
electrolysis needle replace and disinfection
a)electrolysis needle need to disinfect by 75% alcohol or 2% Glutaric dialdehyde.
b)after a period of time, you find the electrolysis needle is not sharp, should rotate electrolysis needle handle by clockwise, taking out the acupuncture needle. Please replace by 0.3x25 No.3acupuncture needles.
Operation
a) environment moisture: 10-30degree
b) relative moisture: below 80%
c)atmospheric pressure: 860hpa degree 1060hpa
d) power: 220V plus 22V 50Hz plus 1Hz
Instrument maintenance and service
a) Instrument should be placed in dry,ventilation,non-corrosive gases place.
b) Before usage, please check treatment pen status on or off, electrolysis sharp etc, in case it will have the bad effect on the treatment.
Storage
a) environment moisture: -10degree-45degree
b) relative moisture: over or below 80%
c) atmospheric pressure:860hpa degree1060hpa d) non-corrosive gas and good ventilation room